Gust effect factor in ASCE-7 - ASCE (civil) Code Issues
Nov 26, 2001 · For rigid structures the ASCE 7,chapter 6 Wind Loads, indicates a gust effect factor of 0.85.My question is how a factor to account for a dynamic effect can be less than 1.0? Thank for any info on this!
ASCE 7-22 Gust Effect Factor - Structural engineering general ...
Aug 22, 2023 · The gust effect factor is based on global dynamic response to wind gustiness, so I would recommend a single factor based on the global natural frequency of the structure.
Crosswind calculation with gust factor. - PPRuNe Forums
Nov 23, 2009 · Questions - Crosswind calculation with gust factor. - Good day all! How do you calculate a crosswind, with wind gust factor? Rwy 03, wind 090/25 gusting 40 kts. Thanks in advance!!!
ASCE 7-05 Gust Effect Factor - Structural engineering general ...
Jul 17, 2010 · I checked the gust factor for a rigid structure and I got 0.90, which is higher than the optional 0.85 factor listed at the beginning of the section. I read the commentary, and it states that the rigid gust effect factor should typically be 0 to 10 percent lower than the 0.85 factor. I checked my calcs and the equations seem to be correct.
Converting Wind Averaging Speeds - Eng-Tips
Oct 15, 2003 · Table 1609.3.1 in the 2003 International Building Code is titled "Equivalent Basic Wind Speeds" and is for converting between fastest mile wind speed and 3-second gust wind speed. The 1.2 factor mentioned by Lutfi seems to work pretty well for a ball park estimate.
Wind Gust Factor for Flexible Buildings - Eng-Tips
Oct 29, 2008 · Thank you for looking at this question! We are trying to repair an existing wood framed picnic shelter canopy that was damaged by wind. It uses wood trusses supported by GL beams supported by GL columns that have corner braces. Unfortunately, it is located close to an escarpment, so we have a...
ASCE 7-02 WIND ON PIPING - ASCE (civil) Code Issues | Eng-Tips
Nov 5, 1999 · I wish to know how to calculate wind gust factor for piping. All data in ASCE are for buildings, but not for piping. Many thank for any informations.
Damping ratio for Gust Effect factor (ASCE 7 wind) - Eng-Tips
Mar 1, 2014 · I am trying to calculate the gust effect factor for a four-legged exterior steel portal frame that supports a large piece of mechanical equipment. The frame consists of steel moment frames in each orthogonal direction (directly welded flanges at HSS tubes) and has bolted shear connections at...
Gust Effect Factor - Monument Sign - Eng-Tips
Apr 18, 2014 · Was hoping to get some input regarding calculating wind loads on a freestanding steel monument sign. The proposed design from the manufacturer is fairly simple, with some decorative tubes surrounding a 6'x7'x½” piece of corten steel. Due to the nature of the construction, we are basically only...
Gust Factor for Flexible Structures: ASCE 7-10 Section 26.9.5 ...
May 3, 2017 · I am creating an excel sheet for calculating the Gust Factor for flexible structures. I have found a video online discussing wind loads on non building structures and in the video they calculate the gust factor for a flexible structure. They do …
- Some results have been removed